ACiQHeat Pump Systems

ACiQ 5 Ton 14.3 SEER2 Central Heat Pump Split System - R32 Inverter - Upflow/Horizontal-Right

System SKU ACIQ60TDHP32ACIQ60TDAH32

Brand
ACiQ
Category
Heat Pump Systems
System SKU
ACIQ60TDHP32ACIQ60TDAH32
Component Model
ACIQ-60TD-HP32
Component Model
ACIQ-60TD-AH32
Heating BTU
54000 BTU
Cooling BTU
54000 BTU
Refrigerant
R32

High-Efficiency Comfort Designed for Simplified Installation

ACiQ 5 Ton 14.3 SEER2 Central Heat Pump Split System - R32 Inverter - Upflow/Horizontal-Right. Full manufacturer copy for this model is not published here yet -- the verified specifications below and the documents on the Resources tab are the authoritative data for it. For application or installation guidance, contact technical support.

ACiQ 5 Ton 14.3 SEER2 Central Heat Pump Split System - R32 Inverter - Upflow/Horizontal-Right

FeatureSpec
ModelACIQ60TDHP32ACIQ60TDAH32
Ambient Temperature Range-4°F - 125°F
Brand/ManufacturerACiQ
Compressor TypeRotary
Condenser StagesTwo Stage
ConfigurationUpflow/Horizontal-Right
ConnectionFlare to Braze
EER28
Electric Backup Heat Capabilities (Optional)5 Kilowatts, 10 Kilowatts, 15 Kilowatts, 20 Kilowatts
Electric HeatHeat Pump
Filter Size20" x 22"
Horsepower1/2 HP
HSPF28.1
Liquid Line3/8"
Liquid Valve Size3/8"
Maximum CFM1,560
Min. Breaker Size35 Amps
Min/Max Outdoor Temp for Cooling5°F - 125°F
Min/Max Outdoor Temp for Heating-4°F - 80°F
MOCP60 Amps
PhaseSingle Phase
Rated Cooling Capacity54000 BTU
Rated Heating Capacity54000 BTU
RefrigerantR32
Refrigerant Charge123.5oz
Safety InformationPROPOSITION 65 WARNING This product and many products on our site may contain a chemical known to the State of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 please Click Here.
SEER2 (Efficiency)14.3
Suction Line7/8"
Suction Valve Size7/8"
Tonnage5 Ton
UPC613,365,209,249
Voltage208/230v 1 Phase 60Hz